
Autocad Hose Reel Drawing
Gleason Reel - CAD files. CAD files are found in the Digital Resources download tool under Engineering Drawings. 2D files are provided in Autodesk's DWG and DXF formats version 2010 and earlier. The Klutch 25-Ft. Dual Hose Reel combines separate steel reels for an air hose and electrical cord into one compact unit. Each reel features auto rewind with ratchet to lock hose or cord at desired length. Includes a 3/8in. 300 PSI rubber air hose and 14/3 AWG, 25ft. Electrical cord with single receptacle.
CONTACTS
| NOTE: Must have AutoCad to open these (.DWG) files |
G01- north arrow | G15- Not used | G28- scale: 1/4' + 1'-0' | G41- door schedule |
G02- detail bubble | G16- title:view | G29- scale: 1/8' + 1'-0' | G41A- door schedule information |
G03- Not used | G17- title:section | G30- scale: 1/16' + 1'-0' | G42- Not used |
G04- cut tails - left | G18- title:detail | G31- scale: 1' + 10'-0' | G43- scale |
G05- cut tails - right | G19- 'A' column call out | G32- scale: 1' + 20'-0' | G44- submittal block |
G06- Not used | G19A- '1' column call out | G33- scale: 1' + 30'-0' | G45- county map |
G07- section cut - right/view down | G20- scale: 1'=1' | G33a- scale: 1' + 40'-0' | G46- key notes 1 |
G08- section cut - right/view up | G21- scale: 1/2'=1' | G34- scale: 1' + 50'-0' | G47- 2 |
G09- section cut - left/view down | G22- scale: 3'=1'-0' | G35- scale: 1' + 60'-0' | G48- Not used |
G10- section cut - left/view up | G23- scale: 1-1/2' + 1'-0' | G36- scale: 1' + 100'-0' | G49- acronyms |
G11- section cut - bottom/view right | G24- scale: 1' + 1'-0' | G37- Not used | G50- product options block |
G12- section cut - top/view right | G25- scale: 3/4 ' + 1'-0' | G38- Key plan | G51- General notes |
G13- section cut - bottom view left | G26- scale: 1/2' + 1'-0' | G39- UCNI stamp | |
G14- section cut - top/view left | G27- scale: 3/8 ' + 1'-0' | G40- 90% review |
ARCHITECTURAL-Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
A01- door no. tag | A03- room no. tag | A04A- shaded view pointer | A06- wall type ID tag |
A02- window type tag | A04- elevation ID tag | A05- vertical elevation ID tag |
CIVIL-Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
C01- benchmark indicator | C010- thrust block | C019- utility water valve | C028- Interstate route |
C02- control elevation indicator | C011- tee fitting | C020- precast-manhole, transformer vault | C029- US route |
C03- monument designator | C012- valve | C021- pull box | C030- State route |
C04- boring indicator | C013- Not used | C022- manhole | C031- existing prop corner |
C05- existing elev. indicator | C014- utility, meter(s) | C023- turning point | C032- new prop corner |
C06- finish elev. indicator | C015- culvert, end | C024- centerline | C033- vault |
C07- steam/comm manhole | C016- drainage arrow | C025- property line | C034- cleanout |
C08- storm drain grate | C017- manhole(s) | C026- flow line | C035- dbl cleanout |
C09- precasts | C018- fire hydrant | C027- handicap | C036- catch basin |
FIRE -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
F001- smoke | F035- emergency light battery | F068- water mist exting- auto | F101- CO2 extinguisher |
F002- 1/2 hour | F036- combined battery light & illuminated exit sign | F069- water mist exting. manual | F102- halon/clean agent extinguisher |
F003- 3/4 hour | F037- manual station | F070- dry chemical sys- auto | F103- extinguisher/metal fires |
F004- 1 hour | F038- carbon dioxide | F071- dry chemical manual | F104- CO2 reel station |
F005- riser | F039- reducer | F072- fires-all (exc metal) auto | F105- dry chemical reel station |
F006- valves, general | F040- alarm gong | F073- fires-all (exc metal) manual | F106- foam reel station |
F007- valve in pit | F041- water monitor alarm | F074- gasious medium - auto | F107- hose station, dry standpipe |
F008- post-indicator valve | F042- phone station | F075- gasious medium - manual | F108- hose station, charged standpipe |
F009- key operated valve | F043- abort switch | F076- halon/clean agent - auto | F109- monitor hose, dry |
F010- OS&Y valve | F044- abort switch (CO2) | F077- halon/clean agent - manual | F110- monitor hose, charged |
F011- butterfly valve | F045- line type detector | F078- fully sprinklered space | F111- purge controls, manual control |
F012- non-indicating valve | F046- smoke detector | F079- partial sprinklered space | F112- fans, general |
F013- check valve | F047- smoke detector duct | F080- nonsprinklered space | F113- duct |
F014- backflow preventer-dbl | F048- gas detector | F081- water spray system | F114- special spray nozzle |
F015- backflow preventer-(RPZ) | F049- flame detector | F082- upright sprinkler | F115- roof fan |
F016- pressure regulator valve | F050- flow detector/switch | F083- pendent sprinkler | F116- wall fan |
F017- pressure relief valve | F051- pressure detector switch | F084- upright sprinkler: nipple up | F117- damper, fire |
F018- float valve | F052- level detector switch | F085- pendent sprinkler: drop nipple | F118- damper, smoke |
F019- meter | F053- tamper detector | F086- sprinkler with guard | F119- damper, fire/smoke |
F020- private hydrant, 1 outlet | F054- valve w/ tamper detector | F087- sidewall sprinkler | F120- damper, barometric |
F021- public hydrant, 2 outlet | F055- door holder | F088- outside sprinkler | F121- pressurized stairwell |
F022- public hydrant, 2 outlet | F056- alarm, manual | F089- pipe hanger | F122- ventilation openings |
F023- wall hydrant, 2 outlet | F057- speaker/horn-elec | F090- angle valve | F123- agent storage container |
F024- private hydrant, 2 outlet | F058- alarm, mini horn | F091- alarm check valve | F124- agent storage: carbon dioxide |
F025- fire dept. 2 outlet/freestand | F059- alarm horn/ light | F092- dry pipe valve | F125- fusible link |
F026- fire dept. 2 outlet | F060- alarm, horn/light - 1 | F093- dry pipe valve w/ quick open | F126- fusible link w/electrothermal |
F027- fire dept. 1 outlet | F061- alarm, lamp/light-sep | F094- deluge valve | F127- solenoid valve |
F028- fire pump with drives | F062- wet charge- auto | F095- preaction valve | F128- features (access etc.) |
F029- freestanding test header | F063- wet charge- manual | F096- Not used | F129- detection/extinguishers |
F030- wall mounted | F064- dry charged- auto | F097- water extinguisher | F130- detection CO2 |
F031- screen/strainer | F065- dry charged- manual | F098- foam extinguisher | F131- water flow control valve |
F032- control panel | F066- foam sys- auto | F099- extinguisher: liquid, gas, electrical | F132- equipment rooms |
F033- illuminated exit sign-single face | F067- foam sys- manual | F100-extinguisher for all fires, except metal | F133- seismic bracing |
F034- illuminated exit sign, dbl face |
ELECTRICAL -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
E001 to E005- Not Used | E040 Ceiling mounted light fixture | E073 End of line device | E104 Normally closed contact | |
E006 Flexible conduit | E041 Wall mounted incandescent fixture | E074 Fire alarm control panel | E105 Normally open contact | |
E007 Conduit down | E042 Emergency light fixture | E075 Fire Alarm Raceway | E106 Protective relay, solenoid coil | |
E008 Conduit up | E043 Light pole with fixture | E075A Clock outlet | E107 Overload relay | |
E009 Not used | E044 Emergency light fixture rechargeable type | E075B Thermostat | E108 Connection | |
E010 Conduit seal | E045 Floodlight | E076 Ceiling speaker | E108A Connection | |
E011 Conduit cap | E046 Ceiling mounted exit sign - arrow as indicated | E077 Wall speaker | E109 Cross, no connection | |
E012 Busway with description | E047 Two faced exit sign | E078 Telecommunications outlet | E109A Cross, no connection | |
E013 Grounding conductor | E048 Wall mounted exit sign | E079 Floor mounted telecommunications outlet | E110 Surge arrestor | |
E014 Cable tray with description | E049 Clearance in front of panel board | E080 Protected transmission system (PTS) data terminal connection | E111 Capacitor | |
E015 Ceiling junction box | E050 Lighting panel - 250 volts or less | E081 Intercom outlet | E112 Relay #1 | |
E016 Wall junction box | E051 Not used | E082 Telephone raceway | E113 Bus plug circuit breaker | |
E017 to E018 Not used | E052 Transformer | E083 Medium-voltage disconnect switch | E114 to E115 Not used | |
E019 Duplex receptacle outlet | E052A Fusible disconnect | E084 Medium-voltage drawout circuit breaker | E116 Electrical equipment designation | |
E020 Single receptacle outlet | E053 Non-fusible disconnect switch (number indicates switch size) | E085 Transformer (delta-wye conn.) | E117 Mechanical equipment designation | |
E021 Double duplex receptacle outlet | E054 Combination magnetic starter and circuit breaker | E086 Shielded transformer | E118 Nameplate designation | |
E022 Ground fault circuit interrupter duplex outlet with weatherproof cover | E055 Magnetic starter (number indicates/NEMA starter size) | E087 Drawout circuit breaker (trip/frame) | E119 to E121 Not used | |
E023 Split wired duplex receptacle | E056 Adjustable speed drive | E087A Motor circuit breaker | E122 Plug-in connector | |
E024 Duplex isolated ground | E057 Automatic Transfer switch | E088 Circuit breaker (trip/frame) | E123 to E125 Not used | |
E025 Special purpose outlet-use subscript to identify type in specs | E058 Motor (number indicates HP) | E089 Fuse | E126 Heat tape | |
E026 Floor receptacle outlet- used subscript to identify type in specs | E059 Bell | E090 Fusible element | E127 Existing elevation | |
E027 Receptacle raceway | E060 Horn 'H' or Siren 'S' | E091 Fusible disconnect switch | E128 Finished elevation | |
E028 | Single pole switch - use subscript to designate control of particular outlets *=2 double pole switch *=3 three-way switch *=4 four-way switch *=WP Weatherproof switch *=K Key Operated switch How to update ProS Wireless controller Switch. Plug the USB C cable into your ProS Switch Wireless Controller. Download the driver. Click the “Download Update“ button below and then open the downloaded file. Press and hold the left stick (L3), then you can plug your controller into the computer. Start the update. In the driver, Click on « Update». Subsonic v900. | E061 Buzzer | E092 Ground | E129 Not used |
E062 Pushbutton | E093 Generator | E130 Fault Designation | ||
E063 Manual pull station | E094 Current transformer (numbers indicate ratio and quantity) | E131 Not used | ||
E064 Fire Alarm Horn (V=Visual Signal) | E095 Potential transformer (number indicates quantity) | E132 TV wall outlet | ||
E032 Dimmer switch - number indicates wattage | E065 Photoelectric smoke detector | E096 Ammeter switch | E133 Not used | |
E033 Photocell | E066 Ionization smoke detector | E097 Voltmeter switch | E134 Heater | |
E034 Remote control switch 6 pole, 30 amps | E067 Thermal detector | E098 Voltmeter | E135 Transformer on pole | |
E035 2'x4' fluorescent light fixture A-fixture type; 1-circuit number; a switch controlling fixture | E068 Duct smoke detector (photoelectric) | E099 Ammeter | E136 to E141 Not used | |
E036 1'x4' fluorescent strip fixture A-fixture type: 1- circuit number; a switch controlling fixture | E069 Magnetic door holder | E100 Kilowatt meter | E142 Panelboard with main circuit breaker | |
E037 1'x4' wall mounted fluorescent fixture | E070 Pressure switch | E101 Automatic transfer switch | E142A Panelboard with main lugs | |
E038 2'x2' fluorescent light fixture | E071 Flow switch | E102 Kirkley Interlock | E143 Transient voltage Surge suppressor | |
E039 2'x2' fluorescent light fixture A-fixture type; 1-circuit number; a-switch controlling fixture | E072 Valve supervisory switch | E103 Battery | E144 to E208 Not used |
MECHANICAL -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
M001- FD-Floor Drain, FS-Floor Sink, RD-Roof Drain | M021- Control valve (two way) | M045- Not Used | M069- Fire Protection post indicating valve number |
M002- Pendent sprinkler head | M022- Control valve (three way) | M046- Not Used | M070- Block valve number- fire hydrant number |
M003- Sidewall head | M023- Diaphragm valve | M047- Not Used | M071- Water system block valve number |
M004- Upright sprinkler head | M024- Gate valve | M048- Not Used | M072- Not used |
M005- Upright sprinkler head and pendent head below | M025- Gate valve (angle) | M049- Not Used | M073- Key box |
M006- alarm valve | M026- Gate valve (OS&Y) | M050- Automatic air vent | M074- Cap or plug |
M007- dry-pipe valve | M027- Globe valve | M051- Manual air vent | M075- Flexible mechanical coupling |
M008- deluge valve | M028- Globe valve (angle) | M052- Backflow preventer | M076- Rigid mechanical coupling |
M009- Pre-Action valve | M029- Hose bibb w/ vac breaker | M053- Floor cleanout | M077- Elbow turned up |
M010- Fire department connection | M030- Needle valve | M054- Wall cleanout | M078- Elbow turned down |
M011- Fire department connection free standing | M031- Plug valve cock | M055- End of pipe cleanout | M079- Flange connection |
M012- Building Fire Control Panel | M032- Pressure reducing valve | M056- Expansion joint | M080- Reducer - concentric |
M013- Halon Control Panel | M033- Relief of safety valve | M057- Expansion loop | M081- Reducer- eccentric- bottom of pipe level |
M014- Fire hydrant | M034- Solenoid valve | M058- Flexible pipe connection | M082- Reducer- eccentric- top of pipe level |
M015- Post Indicator Valve | M035- Cap | M059- Pipe anchor | M083- Tee-outlet up |
M016- EP, PE, SP, FS, FT, TT, PS, PT, TS | M036 Balancing valve | M060- Pressure gauge with valve | M084- Tee-outlet down |
M016A- other type of switch more than 2 letters | M037- Not Used | M061- Steam trap | M085- Union |
M016B- Other type switch (more than 2 letters w/ numerical tag) | M038- Not Used | M062- Strainer | M086- End of Pipe |
M017- T, H, HS, PS, TS | M039- Not Used | M063- Strainer w/blow-off valve strainer | M087- Direction of Flow |
M017A- Other type sensor (more than 2 letters) | M040- Not Used | M064- Thermometer | M088- Pitch piping down |
M017B- Other type sensor (more than 2 letters w/ numerical tag) | M041- Not Used | M065- Test Plug (press/temp) | M089- Mechanical equipment designation |
M018- Ball valve | M042- Not Used | M066- Temp gauge with valve | M090- Mechanical equipment list |
M019- Butterfly valve | M043- Not Used | M067- Meter | |
M020- Check valve | M044- Not Used | M068- Carbon dioxide suppression system |
PID / PFD -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
LEGEND.dwg | P038-Not Used | P098- Y-strainer | P150- cooling tower |
P001-electromagnetic/sonic | P039- instrument ID table | P099- compressed air | P151- chiller |
P002-undefined digital | P040- valve & instr/ ID letters | P100- ducted air flow from space | P152- horiz. centrifugal pump |
P003-pneumatic signal | P041- 49 Not Used | P101- capped air duct | P153- centrifugal fan w/variable inlet vanes |
P004-hydraulic signal | P050- Not Used | P102- gate valve- open | P154- blower/centrifugal fan |
P005-capillary tube | P051- angle valve | P103- gate valve- closed | P155- rotary pump |
P006-electromagnetic/sonic | P052- butterfly valve | P104- glove valve - open | P156- vertical wet pit pump |
P007-internal system link | P053- rotary valve | P105- glove valve- closed | P157- progressive cavity pump |
P008-mechanical link | P054- 3 way | P106- needle valve - open | P158- vertical sump pump |
P009-pneumatic binary signal | P055- 4 way | P107- needle valve - closed | P159- fluid pump |
P009A-dashed2/electric binary | P056- OS&Y | P108- plug-valve - open | P159A- Not used |
P010-Not Used | P057- diaphragm | P109- plug valve - closed | P160- axial fan |
P011-Electrical Heat Tracing | P058- pressure relief | P110- ball valve- open | P161-axial fan w variable inlet vanes |
P011A- cont/dash 2 steam heat | P059- diaphragm actuator | P111- ball valve- closed | P162- 2-stage reciprocating air compressor |
P012-discrete instrum/primary location/accessible | P060-2 way, fail closed | P112- check valve | P163- single stage reciprocating air compressor |
P013-shared display/primary location/accessible | P061- 2 way, fail open | P113- spring check valve | P164- 2-stage rotary tooth air compressor |
P014- computer/ primary location/accessible | P062- 3 way, w diaphragm | P114- angle-valve- open | P165- reciprocating pump |
P015-programmable logic/ primary location/accessible | P063- 4 way, w diaphragm | P115- angle valve- closed | P166- pressure vessels, vertical or horizontal |
P016-discrete instr./field mounted | P064- spring opposed, single actuator | P116- safety/relief valve (inlet port shown closed) | P167- tank |
P017-shared display/field mounted | P065- spring-opposed, double actuator | P117- 3-way valve (closed port darkened) | P168- HVAC coils, (HW, DX, CH, STM, HCL, CCL) |
P018- computer/field mounted | P066- electrohydraulic actuator | P118- 4-way valve (arrows indicate flow) | P169- unit heater (HW, DX, STM, HCL) |
P019- programmatic logic/field mounted | P067- hand actuator or wheel | P119- ball check valve | P170- pressure gas bottle |
P020-discrete instr./primary location /accessible | P068- restriction orifice | P120- dual purge valve | P171- double containment tank |
P021- shared display/primary location /accessible | P069- restriction orifice drilled in valve | P121- alarm valve | P172- humidifier |
P022-computer/primary location / accessible | P070-flow straightening valve | P122- air intake filter | P173- Manual balance damper |
P023-programmable logic/primary location/accessible | P071- diaphragm pressure balanced | P123- alarm | P174- Not used |
P024-discrete instr./primary location/ accessible | P072- pressure-reducing regulator self-contained/adjustable set-point | P124- bubble gauge | P175- multi-point pilot tube array |
P025-shared display/primary location/accessible | P073- pressure reducing regulator w/ external pressure tap | P125- in-line filter | P176-damper |
P026-computer/primary location/ accessible | P074- differential pressure regulator | P126- atmospheric filter | P177- Not used |
P027- programmable logic / primary location/accessible | P075- back pressure regulator - self contained | P127- double basket strainer | P178-evaporative air cooler |
P028-flow indicator for P016 | P076- back pressure regulator - w/external tap | P128- hose reel | P179- opposing blade damper |
P029-instruments common housing | P077- pressure reducing regulator w/integral outlet pressure relief | P129- open drain (schematic) | P180- back draft damper |
P030-patchboard - point 12 | P078- pressure indicator | P130- drain system annotations | P181- separator |
P031-purge/reset/interlock | P079- flow direction | P131- drain (plan view) | P182- single duct variable volume box |
P031A-signal directional | P080- pressure relief or safety valve | P132- cleanout (plan view) | P183- wing type face and bypass damper |
P032 - S/ D/ P/ T/ M/ SP | P081- vacuum relief valve | P133- sanitary vent | P184- collection bin |
P032A- root extraction | P082- pressure/safety valve, straight through w/integral pilot | P134- silencer/muffler | P185- cyclone separator |
P032B-bias | P083- rupture disk/safety head for vacuum relief | P135- space penetrations | P186- fluid recovery pump |
P032C-multiply | P084- rupture disk/safety head for pressure relief | P136- fixed louvers | P187- dual service heat exchanger |
P032D- high selecting | P085- pilot light | P137- trap XX annotates | P187A- single service heat exchanger |
P032E- low selecting | P086- flex connection (rubber) | P138- lubricator | P188-multi-blade damper |
P032F- high limiting | P087- flex connection | P139- 55 gallon drum | P189-opposing blade damper |
P032G- low limiting | P088- single or venturi pilot tube | P140- thermostatic vent | P190- single blade damper |
P032H- proportional | P089- flow meter | P141- sprinkler alarm | P191-motor |
P032I- reverse proportional | P090- reducer | P142- flow alarm valve | P192- test port |
P032J- summing | P091- screwed cap | P143- flow control valve | P193- infrared heater |
P032K- dividing | P092- hose connection | P144- suction diffuser | P194-heater |
P033- equipment tag | P093- pipe cap | P145- automatic air vent | P195-diaphragm lined tank |
P034- piping class break or ML change | P094- hose connection | P146- balancing valve | P196-mist eliminator |
P035-pipe/wire continued, arrowpoint right | P095- flanged connection (piping or equip) | P147- gas plub | P197-HEPA filter |
P036- pipe/wire continued, arrowpoint left | P096- flow orifice fixed | P148 Not used | P198- carbon absorber filter |
P037- pipe/wire continued, arrowpoint both | P097- strainer with valve | P149 Not used | P199- filter |
PLUMBING -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
PL001-drains | PL017-relief or safety valve | PL033-expansion loop | PL049-elbow-turned down |
PL002- ball valve | PL018-solenoid valve | PL034-flexible pipe connection | PL050-flange connection |
PL003-butterfly valve | PL019-switch(es) | PL035-pipe anchor | PL051-reducer-concentric |
PL004-check valve | PL020-switch w/2+ letters | PL036-pressure gauge w/valve | PL052-reducer-eccentric/bottom |
PL005-control valve(2-way) | PL021-switch w/2+ tags | PL037-steam trap | PL053-reducer-eccentric/top |
PL006-control valve (3-way) | PL022-thermostat/sensors | PL038-strainer | PL054-tee - outlet up |
PL007-diaphram valve | PL023-sensors w/2+ letters | PL039-strainer w/blowoff valve | PL055-tee - outlet down |
PL008-gate valve | PL024-sensors w/2+ and tag | PL040-thermometer | PL056-union |
PL009-gate valve (angle) | PL025-automatic air vent | PL041-test plug (press/temp) | PL057-flanged union |
PL010-gate valve (OS&Y) | PL026-manual air vent | PL042-temp gauge with valve | PL058-not used |
PL011- glove valve | PL027-backflow preventer | PL043-meter | PL059-direction of flow |
PL012-glove valve (angle) | PL028-floor cleanout | PL044-carbon dioxide suppression | PL060-pitch piping down |
PL013-hose bibb w/vac breaker | PL029-double cleanout | PL045-cap on end of pipe | PL061-plumbing equipment designation |
PL014-needle valve | PL030-wall clean out | PL046-flexible mechanical coupling | PL062-gas plug |
PL015-plug valve cock | PL031-end of pipe clean out | PL047-rigid mechanical coupling | PL063-balancing valve |
PL016-pressure reducing valve | PL032-expansion joint | PL048-elbow-turned up | PL064 thru 099 - Not used |
PL100-plumbing equipment list |
STRUCTURAL -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 />Committee Members
NONE at this time |
WELDING -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
W001- basic back arrow side | W010- flare bevel, both sides | W019-supplementary concave | W028- groove flare V, other side |
W002- basic fillet, arrow side | W011- groove flare V, arrow side | W020-supplementary convex | W029-single bevel groove, other side |
W003- basic fillet, both sides | W012- groove flare V, both sides | W021-supplementary field welded | W030- single J groove, other side |
W004- basic plug or slot, arrow side | W013- single bevel groove, arrow side | W022-supplementary flush | W031- single U groove, other side |
W005- double bevel fillet, both sides | W014- single J groove, arrow side | W023-supplementary, all around | W032- single V groove, other side |
W006- double J groove, both sides | W015- single U groove, arrow side | W024- basic back, other side | W033- square groove, other side |
W007- double U groove, both sides | W016- single V groove, arrow side | W025- basic fillet, other side | W034- groove flare V, other side |
W008- double V groove, both sides | W017- square groove, arrow side | W026- basic plug or slot, other side | |
W009- flare bevel, arrow side | W018- square groove, both sides | W027- flare bevel, other side |
CONTACTS
| NOTE: Must have AutoCad to open these (.DWG) files |
G01- north arrow | G15- Not used | G28- scale: 1/4' + 1'-0' | G41- door schedule |
G02- detail bubble | G16- title:view | G29- scale: 1/8' + 1'-0' | G41A- door schedule information |
G03- Not used | G17- title:section | G30- scale: 1/16' + 1'-0' | G42- Not used |
G04- cut tails - left | G18- title:detail | G31- scale: 1' + 10'-0' | G43- scale |
G05- cut tails - right | G19- 'A' column call out | G32- scale: 1' + 20'-0' | G44- submittal block |
G06- Not used | G19A- '1' column call out | G33- scale: 1' + 30'-0' | G45- county map |
G07- section cut - right/view down | G20- scale: 1'=1' | G33a- scale: 1' + 40'-0' | G46- key notes 1 |
G08- section cut - right/view up | G21- scale: 1/2'=1' | G34- scale: 1' + 50'-0' | G47- 2 |
G09- section cut - left/view down | G22- scale: 3'=1'-0' | G35- scale: 1' + 60'-0' | G48- Not used |
G10- section cut - left/view up | G23- scale: 1-1/2' + 1'-0' | G36- scale: 1' + 100'-0' | G49- acronyms |
G11- section cut - bottom/view right | G24- scale: 1' + 1'-0' | G37- Not used | G50- product options block |
G12- section cut - top/view right | G25- scale: 3/4 ' + 1'-0' | G38- Key plan | G51- General notes |
G13- section cut - bottom view left | G26- scale: 1/2' + 1'-0' | G39- UCNI stamp | |
G14- section cut - top/view left | G27- scale: 3/8 ' + 1'-0' | G40- 90% review |
ARCHITECTURAL-Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
A01- door no. tag | A03- room no. tag | A04A- shaded view pointer | A06- wall type ID tag |
A02- window type tag | A04- elevation ID tag | A05- vertical elevation ID tag |
CIVIL-Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
C01- benchmark indicator | C010- thrust block | C019- utility water valve | C028- Interstate route |
C02- control elevation indicator | C011- tee fitting | C020- precast-manhole, transformer vault | C029- US route |
C03- monument designator | C012- valve | C021- pull box | C030- State route |
C04- boring indicator | C013- Not used | C022- manhole | C031- existing prop corner |
C05- existing elev. indicator | C014- utility, meter(s) | C023- turning point | C032- new prop corner |
C06- finish elev. indicator | C015- culvert, end | C024- centerline | C033- vault |
C07- steam/comm manhole | C016- drainage arrow | C025- property line | C034- cleanout |
C08- storm drain grate | C017- manhole(s) | C026- flow line | C035- dbl cleanout |
C09- precasts | C018- fire hydrant | C027- handicap | C036- catch basin |
FIRE -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
F001- smoke | F035- emergency light battery | F068- water mist exting- auto | F101- CO2 extinguisher |
F002- 1/2 hour | F036- combined battery light & illuminated exit sign | F069- water mist exting. manual | F102- halon/clean agent extinguisher |
F003- 3/4 hour | F037- manual station | F070- dry chemical sys- auto | F103- extinguisher/metal fires |
F004- 1 hour | F038- carbon dioxide | F071- dry chemical manual | F104- CO2 reel station |
F005- riser | F039- reducer | F072- fires-all (exc metal) auto | F105- dry chemical reel station |
F006- valves, general | F040- alarm gong | F073- fires-all (exc metal) manual | F106- foam reel station |
F007- valve in pit | F041- water monitor alarm | F074- gasious medium - auto | F107- hose station, dry standpipe |
F008- post-indicator valve | F042- phone station | F075- gasious medium - manual | F108- hose station, charged standpipe |
F009- key operated valve | F043- abort switch | F076- halon/clean agent - auto | F109- monitor hose, dry |
F010- OS&Y valve | F044- abort switch (CO2) | F077- halon/clean agent - manual | F110- monitor hose, charged |
F011- butterfly valve | F045- line type detector | F078- fully sprinklered space | F111- purge controls, manual control |
F012- non-indicating valve | F046- smoke detector | F079- partial sprinklered space | F112- fans, general |
F013- check valve | F047- smoke detector duct | F080- nonsprinklered space | F113- duct |
F014- backflow preventer-dbl | F048- gas detector | F081- water spray system | F114- special spray nozzle |
F015- backflow preventer-(RPZ) | F049- flame detector | F082- upright sprinkler | F115- roof fan |
F016- pressure regulator valve | F050- flow detector/switch | F083- pendent sprinkler | F116- wall fan |
F017- pressure relief valve | F051- pressure detector switch | F084- upright sprinkler: nipple up | F117- damper, fire |
F018- float valve | F052- level detector switch | F085- pendent sprinkler: drop nipple | F118- damper, smoke |
F019- meter | F053- tamper detector | F086- sprinkler with guard | F119- damper, fire/smoke |
F020- private hydrant, 1 outlet | F054- valve w/ tamper detector | F087- sidewall sprinkler | F120- damper, barometric |
F021- public hydrant, 2 outlet | F055- door holder | F088- outside sprinkler | F121- pressurized stairwell |
F022- public hydrant, 2 outlet | F056- alarm, manual | F089- pipe hanger | F122- ventilation openings |
F023- wall hydrant, 2 outlet | F057- speaker/horn-elec | F090- angle valve | F123- agent storage container |
F024- private hydrant, 2 outlet | F058- alarm, mini horn | F091- alarm check valve | F124- agent storage: carbon dioxide |
F025- fire dept. 2 outlet/freestand | F059- alarm horn/ light | F092- dry pipe valve | F125- fusible link |
F026- fire dept. 2 outlet | F060- alarm, horn/light - 1 | F093- dry pipe valve w/ quick open | F126- fusible link w/electrothermal |
F027- fire dept. 1 outlet | F061- alarm, lamp/light-sep | F094- deluge valve | F127- solenoid valve |
F028- fire pump with drives | F062- wet charge- auto | F095- preaction valve | F128- features (access etc.) |
F029- freestanding test header | F063- wet charge- manual | F096- Not used | F129- detection/extinguishers |
F030- wall mounted | F064- dry charged- auto | F097- water extinguisher | F130- detection CO2 |
F031- screen/strainer | F065- dry charged- manual | F098- foam extinguisher | F131- water flow control valve |
F032- control panel | F066- foam sys- auto | F099- extinguisher: liquid, gas, electrical | F132- equipment rooms |
F033- illuminated exit sign-single face | F067- foam sys- manual | F100-extinguisher for all fires, except metal | F133- seismic bracing |
F034- illuminated exit sign, dbl face |
ELECTRICAL -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
E001 to E005- Not Used | E040 Ceiling mounted light fixture | E073 End of line device | E104 Normally closed contact | |
E006 Flexible conduit | E041 Wall mounted incandescent fixture | E074 Fire alarm control panel | E105 Normally open contact | |
E007 Conduit down | E042 Emergency light fixture | E075 Fire Alarm Raceway | E106 Protective relay, solenoid coil | |
E008 Conduit up | E043 Light pole with fixture | E075A Clock outlet | E107 Overload relay | |
E009 Not used | E044 Emergency light fixture rechargeable type | E075B Thermostat | E108 Connection | |
E010 Conduit seal | E045 Floodlight | E076 Ceiling speaker | E108A Connection | |
E011 Conduit cap | E046 Ceiling mounted exit sign - arrow as indicated | E077 Wall speaker | E109 Cross, no connection | |
E012 Busway with description | E047 Two faced exit sign | E078 Telecommunications outlet | E109A Cross, no connection | |
E013 Grounding conductor | E048 Wall mounted exit sign | E079 Floor mounted telecommunications outlet | E110 Surge arrestor | |
E014 Cable tray with description | E049 Clearance in front of panel board | E080 Protected transmission system (PTS) data terminal connection | E111 Capacitor | |
E015 Ceiling junction box | E050 Lighting panel - 250 volts or less | E081 Intercom outlet | E112 Relay #1 | |
E016 Wall junction box | E051 Not used | E082 Telephone raceway | E113 Bus plug circuit breaker | |
E017 to E018 Not used | E052 Transformer | E083 Medium-voltage disconnect switch | E114 to E115 Not used | |
E019 Duplex receptacle outlet | E052A Fusible disconnect | E084 Medium-voltage drawout circuit breaker | E116 Electrical equipment designation | |
E020 Single receptacle outlet | E053 Non-fusible disconnect switch (number indicates switch size) | E085 Transformer (delta-wye conn.) | E117 Mechanical equipment designation | |
E021 Double duplex receptacle outlet | E054 Combination magnetic starter and circuit breaker | E086 Shielded transformer | E118 Nameplate designation | |
E022 Ground fault circuit interrupter duplex outlet with weatherproof cover | E055 Magnetic starter (number indicates/NEMA starter size) | E087 Drawout circuit breaker (trip/frame) | E119 to E121 Not used | |
E023 Split wired duplex receptacle | E056 Adjustable speed drive | E087A Motor circuit breaker | E122 Plug-in connector | |
E024 Duplex isolated ground | E057 Automatic Transfer switch | E088 Circuit breaker (trip/frame) | E123 to E125 Not used | |
E025 Special purpose outlet-use subscript to identify type in specs | E058 Motor (number indicates HP) | E089 Fuse | E126 Heat tape | |
E026 Floor receptacle outlet- used subscript to identify type in specs | E059 Bell | E090 Fusible element | E127 Existing elevation | |
E027 Receptacle raceway | E060 Horn 'H' or Siren 'S' | E091 Fusible disconnect switch | E128 Finished elevation | |
E028 | Single pole switch - use subscript to designate control of particular outlets *=2 double pole switch *=3 three-way switch *=4 four-way switch *=WP Weatherproof switch *=K Key Operated switch | E061 Buzzer | E092 Ground | E129 Not used |
E062 Pushbutton | E093 Generator | E130 Fault Designation | ||
E063 Manual pull station | E094 Current transformer (numbers indicate ratio and quantity) | E131 Not used | ||
E064 Fire Alarm Horn (V=Visual Signal) | E095 Potential transformer (number indicates quantity) | E132 TV wall outlet | ||
E032 Dimmer switch - number indicates wattage | E065 Photoelectric smoke detector | E096 Ammeter switch | E133 Not used | |
E033 Photocell | E066 Ionization smoke detector | E097 Voltmeter switch | E134 Heater | |
E034 Remote control switch 6 pole, 30 amps | E067 Thermal detector | E098 Voltmeter | E135 Transformer on pole | |
E035 2'x4' fluorescent light fixture A-fixture type; 1-circuit number; a switch controlling fixture | E068 Duct smoke detector (photoelectric) | E099 Ammeter | E136 to E141 Not used | |
E036 1'x4' fluorescent strip fixture A-fixture type: 1- circuit number; a switch controlling fixture | E069 Magnetic door holder | E100 Kilowatt meter | E142 Panelboard with main circuit breaker | |
E037 1'x4' wall mounted fluorescent fixture | E070 Pressure switch | E101 Automatic transfer switch | E142A Panelboard with main lugs | |
E038 2'x2' fluorescent light fixture | E071 Flow switch | E102 Kirkley Interlock | E143 Transient voltage Surge suppressor | |
E039 2'x2' fluorescent light fixture A-fixture type; 1-circuit number; a-switch controlling fixture | E072 Valve supervisory switch | E103 Battery | E144 to E208 Not used |
MECHANICAL -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
M001- FD-Floor Drain, FS-Floor Sink, RD-Roof Drain | M021- Control valve (two way) | M045- Not Used | M069- Fire Protection post indicating valve number |
M002- Pendent sprinkler head | M022- Control valve (three way) | M046- Not Used | M070- Block valve number- fire hydrant number |
M003- Sidewall head | M023- Diaphragm valve | M047- Not Used | M071- Water system block valve number |
M004- Upright sprinkler head | M024- Gate valve | M048- Not Used | M072- Not used |
M005- Upright sprinkler head and pendent head below | M025- Gate valve (angle) | M049- Not Used | M073- Key box |
M006- alarm valve | M026- Gate valve (OS&Y) | M050- Automatic air vent | M074- Cap or plug |
M007- dry-pipe valve | M027- Globe valve | M051- Manual air vent | M075- Flexible mechanical coupling |
M008- deluge valve | M028- Globe valve (angle) | M052- Backflow preventer | M076- Rigid mechanical coupling |
M009- Pre-Action valve | M029- Hose bibb w/ vac breaker | M053- Floor cleanout | M077- Elbow turned up |
M010- Fire department connection | M030- Needle valve | M054- Wall cleanout | M078- Elbow turned down |
M011- Fire department connection free standing | M031- Plug valve cock | M055- End of pipe cleanout | M079- Flange connection |
M012- Building Fire Control Panel | M032- Pressure reducing valve | M056- Expansion joint | M080- Reducer - concentric |
M013- Halon Control Panel | M033- Relief of safety valve | M057- Expansion loop | M081- Reducer- eccentric- bottom of pipe level |
M014- Fire hydrant | M034- Solenoid valve | M058- Flexible pipe connection | M082- Reducer- eccentric- top of pipe level |
M015- Post Indicator Valve | M035- Cap | M059- Pipe anchor | M083- Tee-outlet up |
M016- EP, PE, SP, FS, FT, TT, PS, PT, TS | M036 Balancing valve | M060- Pressure gauge with valve | M084- Tee-outlet down |
M016A- other type of switch more than 2 letters | M037- Not Used | M061- Steam trap | M085- Union |
M016B- Other type switch (more than 2 letters w/ numerical tag) | M038- Not Used | M062- Strainer | M086- End of Pipe |
M017- T, H, HS, PS, TS | M039- Not Used | M063- Strainer w/blow-off valve strainer | M087- Direction of Flow |
M017A- Other type sensor (more than 2 letters) | M040- Not Used | M064- Thermometer | M088- Pitch piping down |
M017B- Other type sensor (more than 2 letters w/ numerical tag) | M041- Not Used | M065- Test Plug (press/temp) | M089- Mechanical equipment designation |
M018- Ball valve | M042- Not Used | M066- Temp gauge with valve | M090- Mechanical equipment list |
M019- Butterfly valve | M043- Not Used | M067- Meter | |
M020- Check valve | M044- Not Used | M068- Carbon dioxide suppression system |
PID / PFD -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
LEGEND.dwg | P038-Not Used | P098- Y-strainer | P150- cooling tower |
P001-electromagnetic/sonic | P039- instrument ID table | P099- compressed air | P151- chiller |
P002-undefined digital | P040- valve & instr/ ID letters | P100- ducted air flow from space | P152- horiz. centrifugal pump |
P003-pneumatic signal | P041- 49 Not Used | P101- capped air duct | P153- centrifugal fan w/variable inlet vanes |
P004-hydraulic signal | P050- Not Used | P102- gate valve- open | P154- blower/centrifugal fan |
P005-capillary tube | P051- angle valve | P103- gate valve- closed | P155- rotary pump |
P006-electromagnetic/sonic | P052- butterfly valve | P104- glove valve - open | P156- vertical wet pit pump |
P007-internal system link | P053- rotary valve | P105- glove valve- closed | P157- progressive cavity pump |
P008-mechanical link | P054- 3 way | P106- needle valve - open | P158- vertical sump pump |
P009-pneumatic binary signal | P055- 4 way | P107- needle valve - closed | P159- fluid pump |
P009A-dashed2/electric binary | P056- OS&Y | P108- plug-valve - open | P159A- Not used |
P010-Not Used | P057- diaphragm | P109- plug valve - closed | P160- axial fan |
P011-Electrical Heat Tracing | P058- pressure relief | P110- ball valve- open | P161-axial fan w variable inlet vanes |
P011A- cont/dash 2 steam heat | P059- diaphragm actuator | P111- ball valve- closed | P162- 2-stage reciprocating air compressor |
P012-discrete instrum/primary location/accessible | P060-2 way, fail closed | P112- check valve | P163- single stage reciprocating air compressor |
P013-shared display/primary location/accessible | P061- 2 way, fail open | P113- spring check valve | P164- 2-stage rotary tooth air compressor |
P014- computer/ primary location/accessible | P062- 3 way, w diaphragm | P114- angle-valve- open | P165- reciprocating pump |
P015-programmable logic/ primary location/accessible | P063- 4 way, w diaphragm | P115- angle valve- closed | P166- pressure vessels, vertical or horizontal |
P016-discrete instr./field mounted | P064- spring opposed, single actuator | P116- safety/relief valve (inlet port shown closed) | P167- tank |
P017-shared display/field mounted | P065- spring-opposed, double actuator | P117- 3-way valve (closed port darkened) | P168- HVAC coils, (HW, DX, CH, STM, HCL, CCL) |
P018- computer/field mounted | P066- electrohydraulic actuator | P118- 4-way valve (arrows indicate flow) | P169- unit heater (HW, DX, STM, HCL) |
P019- programmatic logic/field mounted | P067- hand actuator or wheel | P119- ball check valve | P170- pressure gas bottle |
P020-discrete instr./primary location /accessible | P068- restriction orifice | P120- dual purge valve | P171- double containment tank |
P021- shared display/primary location /accessible | P069- restriction orifice drilled in valve | P121- alarm valve | P172- humidifier |
P022-computer/primary location / accessible | P070-flow straightening valve | P122- air intake filter | P173- Manual balance damper |
P023-programmable logic/primary location/accessible | P071- diaphragm pressure balanced | P123- alarm | P174- Not used |
P024-discrete instr./primary location/ accessible | P072- pressure-reducing regulator self-contained/adjustable set-point | P124- bubble gauge | P175- multi-point pilot tube array |
P025-shared display/primary location/accessible | P073- pressure reducing regulator w/ external pressure tap | P125- in-line filter | P176-damper |
P026-computer/primary location/ accessible | P074- differential pressure regulator | P126- atmospheric filter | P177- Not used |
P027- programmable logic / primary location/accessible | P075- back pressure regulator - self contained | P127- double basket strainer | P178-evaporative air cooler |
P028-flow indicator for P016 | P076- back pressure regulator - w/external tap | P128- hose reel | P179- opposing blade damper |
P029-instruments common housing | P077- pressure reducing regulator w/integral outlet pressure relief | P129- open drain (schematic) | P180- back draft damper |
P030-patchboard - point 12 | P078- pressure indicator | P130- drain system annotations | P181- separator |
P031-purge/reset/interlock | P079- flow direction | P131- drain (plan view) | P182- single duct variable volume box |
P031A-signal directional | P080- pressure relief or safety valve | P132- cleanout (plan view) | P183- wing type face and bypass damper |
P032 - S/ D/ P/ T/ M/ SP | P081- vacuum relief valve | P133- sanitary vent | P184- collection bin |
P032A- root extraction | P082- pressure/safety valve, straight through w/integral pilot | P134- silencer/muffler | P185- cyclone separator |
P032B-bias | P083- rupture disk/safety head for vacuum relief | P135- space penetrations | P186- fluid recovery pump |
P032C-multiply | P084- rupture disk/safety head for pressure relief | P136- fixed louvers | P187- dual service heat exchanger |
P032D- high selecting | P085- pilot light | P137- trap XX annotates | P187A- single service heat exchanger |
P032E- low selecting | P086- flex connection (rubber) | P138- lubricator | P188-multi-blade damper |
P032F- high limiting | P087- flex connection | P139- 55 gallon drum | P189-opposing blade damper |
P032G- low limiting | P088- single or venturi pilot tube | P140- thermostatic vent | P190- single blade damper |
P032H- proportional | P089- flow meter | P141- sprinkler alarm | P191-motor |
P032I- reverse proportional | P090- reducer | P142- flow alarm valve | P192- test port |
P032J- summing | P091- screwed cap | P143- flow control valve | P193- infrared heater |
P032K- dividing | P092- hose connection | P144- suction diffuser | P194-heater |
P033- equipment tag | P093- pipe cap | P145- automatic air vent | P195-diaphragm lined tank |
P034- piping class break or ML change | P094- hose connection | P146- balancing valve | P196-mist eliminator |
P035-pipe/wire continued, arrowpoint right | P095- flanged connection (piping or equip) | P147- gas plub | P197-HEPA filter |
P036- pipe/wire continued, arrowpoint left | P096- flow orifice fixed | P148 Not used | P198- carbon absorber filter |
P037- pipe/wire continued, arrowpoint both | P097- strainer with valve | P149 Not used | P199- filter |
PLUMBING -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
PL001-drains | PL017-relief or safety valve | PL033-expansion loop | PL049-elbow-turned down |
PL002- ball valve | PL018-solenoid valve | PL034-flexible pipe connection | PL050-flange connection |
PL003-butterfly valve | PL019-switch(es) | PL035-pipe anchor | PL051-reducer-concentric |
PL004-check valve | PL020-switch w/2+ letters | PL036-pressure gauge w/valve | PL052-reducer-eccentric/bottom |
PL005-control valve(2-way) | PL021-switch w/2+ tags | PL037-steam trap | PL053-reducer-eccentric/top |
PL006-control valve (3-way) | PL022-thermostat/sensors | PL038-strainer | PL054-tee - outlet up |
PL007-diaphram valve | PL023-sensors w/2+ letters | PL039-strainer w/blowoff valve | PL055-tee - outlet down |
PL008-gate valve | PL024-sensors w/2+ and tag | PL040-thermometer | PL056-union |
PL009-gate valve (angle) | PL025-automatic air vent | PL041-test plug (press/temp) | PL057-flanged union |
PL010-gate valve (OS&Y) | PL026-manual air vent | PL042-temp gauge with valve | PL058-not used |
PL011- glove valve | PL027-backflow preventer | PL043-meter | PL059-direction of flow |
PL012-glove valve (angle) | PL028-floor cleanout | PL044-carbon dioxide suppression | PL060-pitch piping down |
PL013-hose bibb w/vac breaker | PL029-double cleanout | PL045-cap on end of pipe | PL061-plumbing equipment designation |
PL014-needle valve | PL030-wall clean out | PL046-flexible mechanical coupling | PL062-gas plug |
PL015-plug valve cock | PL031-end of pipe clean out | PL047-rigid mechanical coupling | PL063-balancing valve |
PL016-pressure reducing valve | PL032-expansion joint | PL048-elbow-turned up | PL064 thru 099 - Not used |
PL100-plumbing equipment list |
STRUCTURAL -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 />Committee Members
NONE at this time |
WELDING -Symbols of the Drafting Manual
POC: Richard Trout, ES-DE, 665-1142 David Smith, ES-DE, 665-5902 Committee Members
W001- basic back arrow side | W010- flare bevel, both sides | W019-supplementary concave | W028- groove flare V, other side |
W002- basic fillet, arrow side | W011- groove flare V, arrow side | W020-supplementary convex | W029-single bevel groove, other side |
W003- basic fillet, both sides | W012- groove flare V, both sides | W021-supplementary field welded | W030- single J groove, other side |
W004- basic plug or slot, arrow side | W013- single bevel groove, arrow side | W022-supplementary flush | W031- single U groove, other side |
W005- double bevel fillet, both sides | W014- single J groove, arrow side | W023-supplementary, all around | W032- single V groove, other side |
W006- double J groove, both sides | W015- single U groove, arrow side | W024- basic back, other side | W033- square groove, other side |
W007- double U groove, both sides | W016- single V groove, arrow side | W025- basic fillet, other side | W034- groove flare V, other side |
W008- double V groove, both sides | W017- square groove, arrow side | W026- basic plug or slot, other side | |
W009- flare bevel, arrow side | W018- square groove, both sides | W027- flare bevel, other side |